Fix2100 Gas Alarm Controller

Product Details
Customization: Available
After-sales Service: Whole Life Technical Support
Warranty: One Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (9)
  • Fix2100 Gas Alarm Controller
  • Fix2100 Gas Alarm Controller
  • Fix2100 Gas Alarm Controller
  • Fix2100 Gas Alarm Controller
  • Fix2100 Gas Alarm Controller
  • Fix2100 Gas Alarm Controller
Find Similar Products
  • Overview
  • Product Description
  • Product Features
  • Main Function
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
FIX2100
Measurement Accuracy
Accuracy: ≤±1% (Current Signal)
Working Mode
Mode: Continuous Monitoring
Signal Type
4-20mA Current Signal (3-Wire Gas Detection Device
Channel Support
4-20mA Current Signal: Supports up to 64 Channels
Signal Output
4-20mA Current Signal Output (Optional)
Recording Details
Alarm Location, Status, Time, Concentration, etc.
Alarm Limits
A1 (Low Alarm) and A2 (High Alarm) Can Be Set Inde
Alarm Function
Alarm Indicators: LED Indicator and Buzzer Sound a
Alarm Output
Output Channels: 2 Sets of Relay Outputs, 2 Adjust
Contact Capacity
Capacity: Nc: 1/14HP, 125V/250VAC, 25VDC
Communication Interface
Data Transmission: Supports 4G, Lora, Bluetooth Wi
Data Recording
Storage: Automatic Storage, Can Store Data with Da
Data Download
Download Support: Supports Measurement Data Downlo
Calibration
Calibration Support: Supports 4mA, 12mA, 20mA Thre
Working Humidity
Humidity Range: 0-95% Rh (No Condensation)
Transport Package
Wooden Case
Specification
Approximate Weight 5.5kg
Trademark
J&X
Origin
China
HS Code
902710090
Production Capacity
300pieces/Month

Product Description

FIX2100 Gas Alarm Controller
 

Product Description

 

The gas alarm controller is suitable for standard 4~20mA current signals and RS485 bus control signals. It utilizes a high-performance microcontroller for control and processing, ensuring stable operation.

The controller connects to gas detectors to continuously monitor toxic and harmful gases in the environment. Based on the received input signals, it displays the concentration of the measured gas and can communicate with an upper computer via RS485 digital signals.


The controller allows for the setting of two-level alarm values. When the monitored gas concentration exceeds the standard, it triggers sound and light alarms according to different alarm levels.

Through the menu, users can query data records, alarm records, system logs, and alarm channels. Additionally, the controller can control external devices, such as queuing systems or other equipment, via relay outputs.

Product Features

Control Screen

  • Equipped with a large 5-inch touch TFT-LCD color display for simple and convenient operation.

Maintenance and Installation

  • Built-in filters and adjustment valves can be replaced on-site without disassembly, suitable for 24/7 industrial online monitoring.
  • Standard 19-inch chassis, available in rack-mounted, desktop, or wall-mounted configurations, adaptable to various industrial environments.

Performance and Accuracy

  • Powered by an embedded 32-bit ultra-low-power microprocessor for minimal detection error and high resolution.
  • Integrated temperature and humidity sensors for real-time environmental monitoring.
  • Intelligent temperature, humidity, and zero-point compensation algorithms, with 2 to 4+ levels of full software auto-calibration, ensuring accurate measurements.

Functionality

  • Supports concentration unit switching between PPM, μmol, mg/m³, %VOL, and mg/L.
  • Supports both Chinese and English operating system interfaces.
  • Automatic data storage with customizable intervals; stores up to 100,000 data points with date and time stamps. With optional micro TF storage card, supports over 10 million data points.

Connectivity and Output

  • Supports USB data download and RS485 output.
  • Compatible with micro portable printers for serial port printing.

Main Function

Alarm Function

  • When the monitored gas concentration exceeds the set first-level (A1 low alarm) or second-level (A2 high alarm) thresholds, the buzzer emits a continuous sound, the concentration alarm indicator lights up, and the general relay activates.
  • If a fault occurs in the gas detector connection (e.g., no signal output, disconnected or shorted transmission lines), the buzzer emits a continuous sound, and the fault indicator lights up.

Main and Backup Power Automatic Switching Function

  • When the main power fails, the controller automatically switches to the backup power. When the main power is restored, it switches back automatically.
  • The working status of the main and backup power is indicated by LEDs.
  • The main power charges the backup power when active, and the backup power switches to a floating state once fully charged.

Alarm Output Control Function

  • Alarm output relays can be extended as needed (customizable) to control external firefighting, ventilation, alarm, or other equipment.

Self-Check Function

  • Upon startup, the controller automatically checks the functionality of its panel indicators, buzzer, and relays.
  • The self-check menu allows manual testing of status indicators, the buzzer, and relays.

Current Calibration Function

  • The controller can calibrate input 4mA and 12mA current signals to ensure signal synchronization.
  • For RS485 signal versions, this function is also supported.

Data Recording Function

  • Historical data records can be queried via the menu, with customizable data storage intervals.
  • When a channel's gas concentration exceeds the set alarm threshold, the system automatically records the channel number, concentration value, and alarm time.

Communication Function

  • The controller has one RS485 interface for easy data transmission to other control devices or computers.
  • Default settings: Address = 5, Baud rate = 115200.

Parameter Setting Function

  • System parameters, such as date/time, measurement range, resolution, alarm levels, channel masking, and installation location, can be viewed and modified at any time.

Other Functions

  • Displays the total number of alarm channels.
  • Optional 4~20mA current signal output.

Product Parameters

  

Power Supply

  • Input Voltage: 100V-220VAC; 50/60Hz
  • Output Power: 24VDC, 500mA

Fuse

  • Rated Current: 10A
  • Dimensions: 5mm × 20mm

Maximum Working Current

Maximum Current: 1.5A (24VDC)

Backup Power

  • Backup Battery: 14.8VDC, 4Ah (lithium battery, optional)

Measurement Accuracy

Accuracy: ≤±1% (current signal)

Working Mode

Mode: Continuous monitoring

Input Signal

Signal Type:
  1. 4-20mA current signal (3-wire gas detection device)
  2. RS485 bus control signal (optional, standard MODBUS protocol)

Control Channel

  • Channel Support:
    1. 4-20mA current signal: Supports up to 64 channels
    2. RS485 bus control signal: Supports 1-255 points

Output Signal

  • Signal Output: 4-20mA current signal output (optional)

Alarm Recording

Recording Details: Alarm location, status, time, concentration, etc.

Alarm Setting

Alarm Limits: A1 (low alarm) and A2 (high alarm) can be set independently

Alarm Function

Alarm Indicators: LED indicator and buzzer sound alarm

Alarm Output

Output Channels: 2 sets of relay outputs, 2 adjustable levels, 8 expandable channels (optional)

Contact Capacity

Capacity: NC: 1/14HP, 125V/250VAC, 25VDC

Communication Interface

  • Data Transmission: Supports 4G, LoRa, Bluetooth wireless transmission (optional)

Data Recording

Storage: Automatic storage, can store data with date and time for at least 1 year

Data Download

  • Download Support: Supports measurement data download

Calibration

Calibration Support: Supports 4mA, 12mA, 20mA three-level current calibration

Working Temperature

Temperature Range: 0°C to +55°C

Working Humidity

Humidity Range: 0-95% RH (no condensation)

Environmental Pressure

Pressure Range: 8-160kPa

Appearance

Material: SPCC (optional 303d or concentration indicator)

Dimensions

  • Standard Size: 300mm (width) × 400mm (height)
  • Optional Size: 320mm (width) × 500mm (height) × 100mm (thickness)

Weight

  • Approximate Weight: 5.5kg

Company Profile


We focus on the market, prioritize quality, drive continuous innovation, master core technologies, and serve our customers with dedication. The company is equipped with the necessary detection equipment and technical capabilities to produce high-quality gas detection instruments, demonstrating professionalism and commitment. With a strong reputation in the gas detection field and high customer recognition, we provide reliable support for pre-sales consultation and after-sales service.

Our product development, design, and research are aligned with market demands as well as quality and technical standards. The instruments feature elegant designs, stable detection performance, and explosion-proof configurations, suitable for both fixed gas detectors and portable devices. Thanks to our consistent product quality, we have obtained national licenses for manufacturing measuring instruments, national explosion-proof electrical product certifications, and qualifications for the installation and maintenance of explosion-proof electrical equipment.

Guided by the service philosophy of "perfection, efficiency, and innovation," we are committed to offering society and enterprises safe and reliable solutions to ensure stable production and secure everyday life.
Fix2100 Gas Alarm Controller
Fix2100 Gas Alarm Controller
Fix2100 Gas Alarm Controller
 
Fix2100 Gas Alarm Controller
Fix2100 Gas Alarm Controller
Fix2100 Gas Alarm Controller

Packaging & Shipping

 

Fix2100 Gas Alarm Controller
Fix2100 Gas Alarm Controller
 

FAQ

1. How can I choose the suitable one?

Dear customer, please tell us your detailed requirements via email or online, and we will recommend the most suitable product according to your request.

2. Is your price competitive?

Dear customer, we ensure to provide you with the best quality products at a competitive price.

3. How can I pay?

Dear customer, we accept various payment methods, including T/T and Western Union.

4. When will I receive the product after payment?

Dear customer, standard models can typically be delivered within 5-7 days. Please contact us for more details on the transport time to your address.

5. How do you deliver the product?

Dear customer, we can deliver by Express, Sea, or Air.

6. Will the product be damaged during transport?

Dear customer, please rest assured. We use standard export packaging to ensure the product's safety during transportation.

7. What should I do if I don't know how to use the product?

Dear customer, please don't worry. A user manual will be included with the product. Additionally, you can contact us for further technical support.

8. What should I do if some parts are broken?

Dear customer, please don't worry. Our products come with a 12-month warranty (excluding wear parts). After the warranty period, you can still purchase replacement parts from us.

9. Can you provide OEM/ODM services?

Yes, we offer product customization services to meet your specific needs.
If you have additional questions, feel free to contact us!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier