The TR-9100 system is a gas composition analysis and safety interlock device specifically designed for the safe operation of cement plants. Tailored to the harsh working conditions of cement plants in China, this solution is based on Juneng Company's mature analytical control technology and sample pretreatment technology, incorporating targeted design. In particular, the innovative sampling probe with minimal maintenance requirements is well-suited for the high-dust and harsh working conditions of cement plants in China.
Cement kilns are major energy consumers among industrial furnaces. Analyzing the gas composition of flue gases at the kiln tail, precalciner, and preheater outlet of dry-process rotary kilns can optimize clinker quality, save energy, reduce emissions, and achieve optimized production control. The temperature of flue gases at the kiln tail can reach 1200°C to 1400°C, with dust concentrations as high as 2000g/m³, and the presence of sulfur dioxide and alkaline corrosive gases makes it one of the most technically challenging sampling and analysis targets. The TR-9100 process analysis system successfully addresses this difficult sampling and analysis challenge.