Gt-Mst 1000A Ether Vapor Alarm

Product Details
Customization: Available
After-sales Service: Whole Life Technical Support
Warranty: One Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (9)
  • Gt-Mst 1000A Ether Vapor Alarm
  • Gt-Mst 1000A Ether Vapor Alarm
  • Gt-Mst 1000A Ether Vapor Alarm
  • Gt-Mst 1000A Ether Vapor Alarm
  • Gt-Mst 1000A Ether Vapor Alarm
  • Gt-Mst 1000A Ether Vapor Alarm
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Common faults and solutions
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
GT-MST 1000A
Working Voltage
(12~24) VDC
Exterior Material
Die-Cast Aluminum
Protection Level
IP65/IP66
Installation Method
Wall Type
Explosion-Proof Form
Explosion-Proof Type
Explosion-Proof Level
Ex dB Iic T6 GB
Transport Package
Wooden Case
Specification
181× 136× 93mm (display type)
Trademark
J&X
Origin
China
HS Code
902710090
Production Capacity
300pieces/Month

Product Description

GT-MST 1000A Ether  vapor alarm

Product Description

 

The instrument provides continuous online monitoring of gas concentrations, displaying real-time concentration levels (display type) and triggering an alarm when the concentration exceeds the preset threshold (alarm type). Additionally, the gas concentration data is transmitted to monitoring equipment via a communication cable for centralized management.

Widely used across industries such as gas, metallurgy, petrochemicals, oil exploration and storage, chemicals, shipbuilding, power, and mining, the instrument features a modular design, advanced digital sensor detection technology, a fully explosion-proof structure, and wall-mounted installation.

Certified with the explosion-proof mark Exdb II CT6 Gb, the instrument is suitable for hazardous environments containing explosive gas mixtures of IIAIIC classifications and temperature groups T1T6 in Zones 1 and 2.

Gt-Mst 1000A Ether Vapor Alarm
Gt-Mst 1000A Ether Vapor Alarm
 

 

Product Parameters

 
Detection method
 
diffusion type, online uninterrupted work
 
Working voltage
 
(12~24) VDC
Working current
 
combustible gas <150mA (Max) / other gas <100mA (Max)
 
Output signal
 
(4~20) mA / RS485 / Powerbus/ XMbus/ CAN / (0~5) V / (0~10) V
Exterior material
 
die-cast aluminum
Exterior dimensions
 
181×136×93mm (display type)
Weight
 
display type ≤1.5kg
 
Connection distance
 
(200~1200) m related to cable material and wiring method
 
Protection level
 
IP65/IP66
Installation method
 
wall type
Explosion-proof form
 
explosion-proof type
 
Explosion-proof level
 
 Ex db IIC T6 Gb
 
Wire inlet
 
hexagonal threading explosion-proof bolt G1/2 (some models are M20*1.5 or G3/4)

Common faults and solutions

 

Fault: The equipment has not been shipped

  • Cause: The instrument was shipped without permission.
  • Solution: Return to the factory for operation.

Fault: The instrument has no output

  • Cause 1: Wire connection error.
    Solution: Reconnect the wires.
  • Cause 2: Circuit failure.
    Solution: Return to the factory for repair.

Fault: There is a reading when there is no gas

  • Cause 1: Zero drift.
    Solution: Perform zero calibration.
  • Cause 2: Circuit failure.
    Solution: Return to the factory for repair.

Fault: The host reading is low

  • Cause 1: Amplification factor is too low.
    Solution: Perform range calibration.
  • Cause 2: Sensor failure.
    Solution: Replace the sensor.

Fault: The host reading is high

  • Cause 1: Amplification factor is too high.
    Solution: Perform range calibration.
  • Cause 2: Sensor failure.
    Solution: Replace the sensor.

Fault: The host reading is unstable

  • Cause 1: Insufficient stabilization time.
    Solution: Power on and wait for stabilization.
  • Cause 2: Sensor failure.
    Solution: Replace the sensor.
  • Cause 3: Circuit failure.
    Solution: Return to the factory for repair.
  • Cause 4: Interference.
    Solution: Ensure the instrument is properly grounded.

Fault: The response time is slow

  • Cause 1: Dust blocking the probe.
    Solution: Clean the dust and keep the probe clean.
  • Cause 2: Sensor failure.
    Solution: Replace the sensor.
  • Cause 3: Circuit failure.
    Solution: Return to the factory for repair.

Company Profile


We focus on the market, prioritize quality, drive continuous innovation, master core technologies, and serve our customers with dedication. The company is equipped with the necessary detection equipment and technical capabilities to produce high-quality gas detection instruments, demonstrating professionalism and commitment. With a strong reputation in the gas detection field and high customer recognition, we provide reliable support for pre-sales consultation and after-sales service.

Our product development, design, and research are aligned with market demands as well as quality and technical standards. The instruments feature elegant designs, stable detection performance, and explosion-proof configurations, suitable for both fixed gas detectors and portable devices. Thanks to our consistent product quality, we have obtained national licenses for manufacturing measuring instruments, national explosion-proof electrical product certifications, and qualifications for the installation and maintenance of explosion-proof electrical equipment.

Guided by the service philosophy of "perfection, efficiency, and innovation," we are committed to offering society and enterprises safe and reliable solutions to ensure stable production and secure everyday life.
Gt-Mst 1000A Ether Vapor Alarm
Gt-Mst 1000A Ether Vapor Alarm
Gt-Mst 1000A Ether Vapor Alarm
 
Gt-Mst 1000A Ether Vapor Alarm
Gt-Mst 1000A Ether Vapor Alarm
Gt-Mst 1000A Ether Vapor Alarm
 

Packaging & Shipping

 

Gt-Mst 1000A Ether Vapor Alarm
Gt-Mst 1000A Ether Vapor Alarm
 

FAQ

 

1. How can I choose the suitable one?

Dear customer, please tell us your detailed requirements via email or online, and we will recommend the most suitable product according to your request.

2. Is your price competitive?

Dear customer, we ensure to provide you with the best quality products at a competitive price.

3. How can I pay?

Dear customer, we accept various payment methods, including T/T and Western Union.

4. When will I receive the product after payment?

Dear customer, standard models can typically be delivered within 5-7 days. Please contact us for more details on the transport time to your address.

5. How do you deliver the product?

Dear customer, we can deliver by Express, Sea, or Air.

6. Will the product be damaged during transport?

Dear customer, please rest assured. We use standard export packaging to ensure the product's safety during transportation.

7. What should I do if I don't know how to use the product?

Dear customer, please don't worry. A user manual will be included with the product. Additionally, you can contact us for further technical support.

8. What should I do if some parts are broken?

Dear customer, please don't worry. Our products come with a 12-month warranty (excluding wear parts). After the warranty period, you can still purchase replacement parts from us.

9. Can you provide OEM/ODM services?

Yes, we offer product customization services to meet your specific needs.
If you have additional questions, feel free to contact us!

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier