Centrifuge Reactor Oxygen Content Analyzer

Product Details
Customization: Available
After-sales Service: Whole Life Technical Support
Warranty: One Year
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (9)
  • Centrifuge Reactor Oxygen Content Analyzer
  • Centrifuge Reactor Oxygen Content Analyzer
  • Centrifuge Reactor Oxygen Content Analyzer
  • Centrifuge Reactor Oxygen Content Analyzer
  • Centrifuge Reactor Oxygen Content Analyzer
  • Centrifuge Reactor Oxygen Content Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Product Applications
  • Working Principle
  • Company Profile
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
XMB-001
Sound and Light Alarm
90 dB
Usage
Mobile
Power Supply
220VAC / 24VDC
Sampling Method
Negative Pressure Suction / Pump Suction
Gas Supply Pressure
0.3 MPa - 0.7 MPa
Appearance Material
Brushed 304 Stainless Steel
Main Body Material
316L Stainless Steel
System Pipeline
8mm Polytetrafluoroethylene (PTFE) Tube
Applicable Range
Suitable for Various Combined Gases, Including Aci
Equipment Size
380mm X 360mm X 1100mm (Customizable)
Equipment Weight
Approx. 45kg
Transport Package
Wooden Case
Specification
1.5kg
Trademark
J&X
Origin
China
HS Code
902710090
Production Capacity
300pieces/Month

Product Description

Centrifuge Reactor Oxygen Content Analyzer

Product Description


The Centrifuge Reactor Oxygen Content Analyzer is designed to precisely meet on-site sampling needs. Simply install a quick-connect throttle valve on the centrifuge or reactor in advance. When oxygen content needs to be measured inside the centrifuge, insert the sampling tube into the throttle valve port, then open the valve to perform online detection.

Unlike the fixed centrifuge oxygen content analyzer, this model offers greater flexibility. It includes a gas sampling pre-treatment system that helps protect the electrochemical sensor of the gas analyzer, ensuring accurate and reliable measurements. To meet on-site sampling needs, simply install a quick-connect throttle valve on the centrifuge or reactor in advance. When internal oxygen content needs to be measured, insert the sampling tube into the throttle valve port and open the valve for real-time online detection.

Product Parameters

 

Header model XP3000
Detection Gas O2
Detection Range 0-30% VOL
Detection Principle Electrochemical
Sensor Brand British CITY
Measurement Accuracy 0.1% VOL
Response Time T90 < 30s
Analog Signal Output 4-20mA
Power Supply DC 8V - 30V
Power Consumption < 5W
Explosion-proof Grade ExdIICT6Gb
Protection Grade IP66
Weight 1.5kg
Ambient Temperature -20°C to +50°C (Avoid direct sunlight)
Ambient Humidity 10% - 93% RH (Non-condensing)

Product Applications

 

  1. Pharmaceutical Industry:
    The centrifuge reactor oxygen content analyzer is used to monitor the oxygen levels during various stages of pharmaceutical production processes.

  2. Biochemical Field:
    This analyzer plays a critical role in the research and production of biochemical technologies, ensuring precise oxygen monitoring for optimal processes.

  3. Environmental Engineering Industry:
    The analyzer is employed to monitor oxygen content in environmental engineering applications, such as the treatment of wastewater and the management of waste gases.

Working Principle

 
  • Gas Sampling:
    A gas sampling system is employed at the laboratory or production site to extract gas from the reactor.

  • Gas Pretreatment:
    The collected gas undergoes pretreatment to remove impurities, such as water vapor, carbon dioxide, and other contaminants.

  • Oxygen Sensor Detection:
    The purified gas is then sent to the oxygen sensor, which detects changes in oxygen content and transmits the data to the data acquisition and processing system.

  • Data Acquisition and Processing:
    The system collects, records, and processes the oxygen content data detected by the oxygen sensor. It generates relevant reports and enables laboratory personnel to analyze trends in oxygen content changes throughout the reaction, as well as its relationship with other process parameters.

  • Control System:
    The data processing system analyzes and evaluates the oxygen content variations during the reaction. When required, the control system can automatically adjust oxygen levels to optimize the reaction process.

Company Profile


We focus on the market, prioritize quality, drive continuous innovation, master core technologies, and serve our customers with dedication. The company is equipped with the necessary detection equipment and technical capabilities to produce high-quality gas detection instruments, demonstrating professionalism and commitment. With a strong reputation in the gas detection field and high customer recognition, we provide reliable support for pre-sales consultation and after-sales service.

Our product development, design, and research are aligned with market demands as well as quality and technical standards. The instruments feature elegant designs, stable detection performance, and explosion-proof configurations, suitable for both fixed gas detectors and portable devices. Thanks to our consistent product quality, we have obtained national licenses for manufacturing measuring instruments, national explosion-proof electrical product certifications, and qualifications for the installation and maintenance of explosion-proof electrical equipment.

Guided by the service philosophy of "perfection, efficiency, and innovation," we are committed to offering society and enterprises safe and reliable solutions to ensure stable production and secure everyday life.
Centrifuge Reactor Oxygen Content Analyzer
Centrifuge Reactor Oxygen Content Analyzer
Centrifuge Reactor Oxygen Content Analyzer
 

Packaging & Shipping

 

Centrifuge Reactor Oxygen Content Analyzer
Centrifuge Reactor Oxygen Content Analyzer

 