Direct-Plug Oxygen Analyzer for Factories

Product Details
Customization: Available
After-sales Service: Whole Life Technical Support
Warranty: One Year
Still deciding? Get samples of US$ 1000/Set
Request Sample
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (9)
  • Direct-Plug Oxygen Analyzer for Factories
  • Direct-Plug Oxygen Analyzer for Factories
  • Direct-Plug Oxygen Analyzer for Factories
Find Similar Products

Basic Info.

Model NO.
XMB-YW-3000
Brand
J&X
Customized
Customized
Portable
Portable
Gas
O2
Type
Direct-Plug Oxygen Analyzer
Measurement Range
0-5%/0-25%
Detection Principle
Fluorescence Quenching, Electrochemistry
Detection Accuracy
1ppm/0.01%Vol
Explosion-Proof Level
Exdibiict6GB
Protection Level
IP 67
Response Time
T90<20s
Signal Output
4-20mA, RS485, Hart Protocol
Switch Output
4 Groups
Rated Voltage
DC24V
Display Mode
OLED
Signal Acquisition
16-Bit ADC Digital-to-Analog Conversion
Transport Package
Wooden Case
Trademark
J&X
Origin
China
HS Code
9027100090
Production Capacity
300peices/Month

Product Description

Direct-plug oxygen analyzer
Direct-Plug Oxygen Analyzer for FactoriesDirect-Plug Oxygen Analyzer for Factories
Brief description:
1. Direct-plug oxygen analyzer is used to detect the oxygen concentration of combustion gas in large or small boilers, various industrial furnaces and combustion devices, or for the control of low-oxygen combustion and the detection of oxygen content in exhaust gas of each system, so as to achieve reasonable low-oxygen combustion, reduce fuel consumption, burn loss, stabilize the process, improve product quality, reduce environmental pollution and other purposes.

2. Direct-plug oxygen analyzer is widely used to detect the oxygen concentration of combustion gas in large or small boilers, various industrial furnaces and combustion devices, or for the control of low-oxygen combustion and the detection of oxygen content in exhaust gas of each system, so as to achieve reasonable low-oxygen combustion, reduce fuel consumption, burn loss, stabilize the process, improve product quality, reduce environmental pollution and other purposes.
Since it is impossible to ensure whether the nitrogen meets the qualified supply input, the traditional continuous nitrogen replacement also has the possibility of explosion. In view of the above situation, our company adopts pre-stage sampling pretreatment + on-site numerical display + automatic nitrogen filling, and can also be transmitted to DCS/GDS through 4-20mA signal according to the matching needs to achieve overall automatic chain control.

3. Direct-insert oxygen analyzer has the characteristics of easy installation, convenient use and high reliability. It is not only widely used in high-energy consumption industries such as steel, electricity, petroleum and petrochemicals, kiln industry, papermaking and pulping, food, fiber, etc., but also in various combustion equipment such as garbage incinerators and small and medium-sized boilers for combustion management or control, and has a very wide range of applications. It has achieved fruitful results in energy conservation and emission reduction. Contribute to preventing climate warming and preventing air pollution.


Direct-insert oxygen analyzer application areas:
1. Reactor nitrogen filling protection system;
2. Nitrogen filling protection in various process processes;
3. Storage tank nitrogen filling protection system


Technical parameters:
Model XMB-YW-3000
Measurement range 0-5%/0-25%
Detection principle fluorescence quenching, electrochemistry
Detection accuracy 1PPm/0.01%VOL
Explosion-proof level ExdibIICT6Gb
Protection level IP 67
Response time T90<20S
Signal output 4-20mA, RS485, HART protocol
Switch output 4 groups (2 groups for use and 2 groups for standby) Rated voltage:DC24V
Display mode OLED
Signal acquisition 16-bit ADC digital-to-analog conversion

Gas detection alarm, gas detector, gas alarm controller, toxic and harmful gas detection alarm, independent  alarm, air quality monitor, infrared gas analyzer in manufacturing environment. Widely used in mining and metallurgy, archaeological exploration, steelmaking,  petrochemical industry, gas, municipal fire protection, refrigeration, cargo ship, pharmaceutical, rubber, hazardous chemical storage, industrial manufacturing and other industrial places that need explosion and poisoning prevention. Survive by quality, continue to innovate, master core technology, and serve attentively. The company has the testing equipment and process conditions for the production of gas detection instruments, and is professional and focused. The company has a high reputation in the field of gas detection and testing and its customer recognition. Some of its products are exported to 13 countries and regions. The company has offices in many cities in China, providing strong guarantees for the pre-consultation and post-service of the products sold. Survive by quality, continue to innovate, master core technologies, and provide attentive service. The company has the testing equipment and process conditions for the production of gas detection instruments, and is professional and focused.
 